Download this document
Be Window Specification Comparison

 

IF-1™

PF-60™

PS-200™

IS-50M™**

Be

99.8%

99.0%

98.5%

99.0%

BeO

600 ppm

8,000 ppm

15,000 ppm

5,000 ppm

Fe

300 ppm

800 ppm

1,300 ppm

1,500 ppm

Al

100 ppm

500 ppm

1,000 ppm

900 ppm

Mg

60 ppm

490 ppm

800 ppm

800 ppm

Si

100 ppm

400 ppm

600 ppm

600 ppm

C

300 ppm

600 ppm

1,500 ppm

1,000 ppm

Cr

35 ppm

100 ppm

400 ppm

Co

5 ppm

10 ppm

10 ppm

Cu

50 ppm

100 ppm

100 ppm

Pb

5 ppm

20 ppm

20 ppm

Mn

30 ppm

100 ppm

200 ppm

Mo

10 ppm

20 ppm

20 ppm

Ni

200 ppm

200 ppm

500 ppm

Ca

200 ppm

100 ppm

200 ppm

Zn

100 ppm

--

200 ppm

Ag

5 ppm

10 ppm

5 ppm

Ti

10 ppm

--

--

B

--

3 ppm

--

Cd

--

2 ppm

--

Li

--

3 ppm

--

U

*<2 ppm

*25-140 ppm

--

--

Th

*<3 ppm

*<2 ppm

--

--

 *Not specified--value
  **Mammography grade beryllium
 †Other metallic impurities comprise less than 400 ppm each as determined by normal spectrographic methods.

HEALTH AND SAFETY

  Handling beryllium in solid form poses no special health risk. Like many industrial materials, beryllium-containing materials may pose a health risk if recommended safe handling practices are not followed. Inhalation of airborne beryllium may cause a serious lung disorder in susceptible individuals. The Occupational Safety and Health Administration (OSHA) has set mandatory limits on occupational respiratory exposures. Read and follow the guidance in the Material Safety Data Sheet (MSDS) before working with this material. For additional information on safe handling practices or technical data on beryllium contact Brush Wellman Inc. - Electrofusion Products.
Brush Wellman Inc. Beryllium Products   Brush Wellman Inc. Electrofusion Products
Ph: (419) 862-4127 or (419) 862-4171 Fax: (419) 862-4174   Ph: (510) 623-1500 Fax: (510) 623-7600